DIGITAL MULTIMETER - CAT III 600 V / CAT IV 300 V - 1999 COUNTS
€64.95
Availability: In stock or 3 working days
SKU
VL_DVM895
| Height | 28.000000 |
|---|---|
| External Id | DVM895 |
| EAN | 5410329642648 |
| Packaging | Coque |
| Width | 18.000000 |
| Depth | 5.500000 |
Product basic info
- Instruction manual languages: Dutch, English, French, German, Polish, Portuguese, Spanish
- Primary colours: Black
- Additional colours: Red
- Depth unit: 40 mm
- Height unit: 190 mm
- Width unit: 100 mm
- Weight unit: 300 g
- Material: ABS
Physical properties
- Cable length: 0.75 m
- Display height: 36 mm
- Display width: 62 mm
- Display type: LCD
- Backlight: Yes
- Maximum digits display: 1999
Electrical data
- AC current: <ul> <li>basic accuracy: ± (1.5% rdg + 3 digits), ± (2.0% rdg + 3 digits) for 200mA range, ± (2.5% rdg + 5 digits) for 15 A range</li> <li>overload protection: 500 mA / 600 V, 15 A / 600 V fuse</li> <li>frequency range: 40-500 Hz</li> </ul>
- AC voltage: <ul> <li>basic accuracy: ± (0.8% rdg + 3 digits) , ± (1.2% rdg + 3 digits) for 600 V range</li> <li>input impedance: 1 megohm for 2 V range, 10 megohm for other ranges</li> <li>frequency range: 40-500 Hz</li> <li>maximum input: 600V DC or AC rms</li><li>test A: <= or <,=</li><li>test B: >= or >,=</li> </ul>
- Audible continuity measurement: Yes
- Audible continuity: <ul> <li>built-in buzzer sounds if resistance is less than 50 Ohm</li> <li>test voltage: approx. 3 V</li> </ul>
- Automatic polarity indication: Yes
- Capacity: <ul> <li>basic accuracy: ± (2.5% rdg + 10 digits) for 2000 pF range, ± (2.5% rdg + 5 digits) for 20nF to 20 µF range, ± (5.0% rdg + 10 digits) for 200 µF range</li> <li>overload protection: 500 mA / 600 V fuse</li> </ul>
- DC current: <ul> <li>basic accuracy: ± (1.2% rdg + 2 digits), ± (1.5% rdg + 2 digits) for 200mA range, ± (2.0% rdg + 3 digits) for 15 A range</li> <li>overload protection: 500 mA / 600 V, 15 A / 600 V fuse</li> </ul>
- DC voltage: <ul> <li>basic accuracy: ± (0.5% rdg + 2 digits) , ±(0.8% rdg + 2 digits) for 600 V range</li> <li>input impedance: 10 MOhm</li> <li>maximum input: 600 V</li> <li>overload protection: 600 V DC or AC rms</li> </ul>
- Diode test: Yes
- Diode test specifications: test voltage: approx. 3 V (reversed DC voltage)<br>
- Frequency: <ul> <li>basic accuracy: ± (2.0% rdg + 5 digits)</li> <li>overload protection: 600 VDC or AC rms</li> <li>sensitivity: sine wave 0.5 V rms</li> </ul>
- Fuse type: F 0.50 A / 600 VAC / 500 VDC, 5 x 20 mm, breaking capacity 1 kA, F 15 A / 1000 VAC / 1000 VDC, 6 x 32 mm, breaking capacity 10 kA
- Out of range indication: Yes
- Temperature measuring Celsius specifications: <ul> <li>-50 - 150 °C / 150 - 800 °C</li> <li>basic accuracy: <ul> <li>± (3 °C + 3 digits) for -50 - 150 °C range</li> <li>± (3 % + 3 digits) for 150 - 800 °C range</li> </ul> </li> <li>overload protection: 500 mA / 600 V fuse</li> <li>NiCr-NiSi sensor</li> <li>K thermocouple probe: included</li> </ul>
- Transistor test: No
- AC current measurements: 15 A, 2 mA, 20 mA, 200 µA, 200 mA
- AC voltage measurements: 0-2 V, 20 V, 200 V, 600 V
- Capacity measurements: 2 µF, 20 nF, 200 µF, 200 nF, 2000 pF
- DC current measurements: 0.2 mA, 15 A, 2 mA, 20 mA, 200 µA, 200 mA
- DC voltage measurements: 0-200 mV, 2 V, 20 V, 200 V, 600 V
- Frequency measurements: 20 kHz
- Resistance measurements: 0-200 Ohm, 2 kOhm, 2 MOhm, 20 kOhm, 20 MOhm, 200 kOhm, 200 MOhm
- Resistance specifications: <ul> <li>basic accuracy: ± ( 1.0% rdg +3 digits) for 200 Ohm range, ± (1.0% rdg + 2 digits) for 2 KOhm to 2 Mohm range, ± (1.5% rdg + 3 digits) for 20 MOhm range, ± (5.0% rdg + 5 digits) for 200 MOhm range</li> <li>overload protection: 600 VDC or AC rms</li> </ul>
Technical data
- Safety rating: Cat III / 600 V, Cat IV / 300 V
- Voltage tester type: AC / DC
- Automatic power-off function: Yes
- Pollution degree: 2
- Data-hold function: No
Environmental data
- IP rating: IPx0
- Usage location: Indoor only
- Operating temperature °C: 0-40 °C
- Operating temperature °F: 32-104 °F
- Storage temperature °C: -20-60 °C
- Storage temperature °F: -4-140 °F
- Maximum storage humidity: < 90 %
- Maximum operating humidity: < 80 %
Operational properties