DIGITAL MULTIMETER - CAT III 600 V / CAT IV 300 V - 1999 COUNTS

€64.95
Availability: In stock or 3 working days
SKU
VL_DVM895
More Information
Height28.000000
External IdDVM895
EAN5410329642648
PackagingCoque
Width18.000000
Depth5.500000
Product basic info
  • Instruction manual languages: Dutch, English, French, German, Polish, Portuguese, Spanish
  • Primary colours: Black
  • Additional colours: Red
  • Depth unit: 40 mm
  • Height unit: 190 mm
  • Width unit: 100 mm
  • Weight unit: 300 g
  • Material: ABS
Physical properties
  • Cable length: 0.75 m
  • Display height: 36 mm
  • Display width: 62 mm
  • Display type: LCD
  • Backlight: Yes
  • Maximum digits display: 1999
Electrical data
  • AC current: <ul> <li>basic accuracy: ± (1.5% rdg + 3 digits), ± (2.0% rdg + 3 digits) for 200mA range, ± (2.5% rdg + 5 digits) for 15 A range</li> <li>overload protection: 500 mA / 600 V, 15 A / 600 V fuse</li> <li>frequency range: 40-500 Hz</li> </ul>
  • AC voltage: <ul> <li>basic accuracy: ± (0.8% rdg + 3 digits) , ± (1.2% rdg + 3 digits) for 600 V range</li> <li>input impedance: 1 megohm for 2 V range, 10 megohm for other ranges</li> <li>frequency range: 40-500 Hz</li> <li>maximum input: 600V DC or AC rms</li><li>test A: <= or &lt,=</li><li>test B: >= or &gt,=</li> </ul>
  • Audible continuity measurement: Yes
  • Audible continuity: <ul> <li>built-in buzzer sounds if resistance is less than 50 Ohm</li> <li>test voltage: approx. 3 V</li> </ul>
  • Automatic polarity indication: Yes
  • Capacity: <ul> <li>basic accuracy: ± (2.5% rdg + 10 digits) for 2000 pF range, ± (2.5% rdg + 5 digits) for 20nF to 20 µF range, ± (5.0% rdg + 10 digits) for 200 µF range</li> <li>overload protection: 500 mA / 600 V fuse</li> </ul>
  • DC current: <ul> <li>basic accuracy: ± (1.2% rdg + 2 digits), ± (1.5% rdg + 2 digits) for 200mA range, ± (2.0% rdg + 3 digits) for 15 A range</li> <li>overload protection: 500 mA / 600 V, 15 A / 600 V fuse</li> </ul>
  • DC voltage: <ul> <li>basic accuracy: ± (0.5% rdg + 2 digits) , ±(0.8% rdg + 2 digits) for 600 V range</li> <li>input impedance: 10 MOhm</li> <li>maximum input: 600 V</li> <li>overload protection: 600 V DC or AC rms</li> </ul>
  • Diode test: Yes
  • Diode test specifications: test voltage: approx. 3 V (reversed DC voltage)<br>
  • Frequency: <ul> <li>basic accuracy: ± (2.0% rdg + 5 digits)</li> <li>overload protection: 600 VDC or AC rms</li> <li>sensitivity: sine wave 0.5 V rms</li> </ul>
  • Fuse type: F 0.50 A / 600 VAC / 500 VDC, 5 x 20 mm, breaking capacity 1 kA, F 15 A / 1000 VAC / 1000 VDC, 6 x 32 mm, breaking capacity 10 kA
  • Out of range indication: Yes
  • Temperature measuring Celsius specifications: <ul> <li>-50 - 150 °C / 150 - 800 °C</li> <li>basic accuracy: <ul> <li>± (3 °C + 3 digits) for -50 - 150 °C range</li> <li>± (3 % + 3 digits) for 150 - 800 °C range</li> </ul> </li> <li>overload protection: 500 mA / 600 V fuse</li> <li>NiCr-NiSi sensor</li> <li>K thermocouple probe: included</li> </ul>
  • Transistor test: No
  • AC current measurements: 15 A, 2 mA, 20 mA, 200 µA, 200 mA
  • AC voltage measurements: 0-2 V, 20 V, 200 V, 600 V
  • Capacity measurements: 2 µF, 20 nF, 200 µF, 200 nF, 2000 pF
  • DC current measurements: 0.2 mA, 15 A, 2 mA, 20 mA, 200 µA, 200 mA
  • DC voltage measurements: 0-200 mV, 2 V, 20 V, 200 V, 600 V
  • Frequency measurements: 20 kHz
  • Resistance measurements: 0-200 Ohm, 2 kOhm, 2 MOhm, 20 kOhm, 20 MOhm, 200 kOhm, 200 MOhm
  • Resistance specifications: <ul> <li>basic accuracy: ± ( 1.0% rdg +3 digits) for 200 Ohm range, ± (1.0% rdg + 2 digits) for 2 KOhm to 2 Mohm range, ± (1.5% rdg + 3 digits) for 20 MOhm range, ± (5.0% rdg + 5 digits) for 200 MOhm range</li> <li>overload protection: 600 VDC or AC rms</li> </ul>
Technical data
  • Safety rating: Cat III / 600 V, Cat IV / 300 V
  • Voltage tester type: AC / DC
  • Automatic power-off function: Yes
  • Pollution degree: 2
  • Data-hold function: No
Environmental data
  • IP rating: IPx0
  • Usage location: Indoor only
  • Operating temperature °C: 0-40 °C
  • Operating temperature °F: 32-104 °F
  • Storage temperature °C: -20-60 °C
  • Storage temperature °F: -4-140 °F
  • Maximum storage humidity: < 90 %
  • Maximum operating humidity: < 80 %
Operational properties